24
OPERATING THE ENGINE
C For SCR system inducement display appearing on LCD, refer to measures of the table below.
On the SCR system, the remaining amount and quality of DEF/AdBlue® as well as machine troubles are monitored. If
anything goes wrong during operation, the following warnings are issued. Follow the warning contents to take proper
measures.
Warning
Displays
indicator
*1 When DEF/AdBlue® has been added or a poor-quality solution replaced by a genuine product, the low-level warning
indicator and icons go off. The engine output limitation will also be cleared.
Status
The amount of remaining DEF/AdBlue® has decreased up
to 15% of the maximum capacity.
1
Refuel the DEF/AdBlue® tank to reset the warning system.
If operation is continued without refueling, the engine output
will be limited.
The amount of remaining DEF/AdBlue® has decreased up
to 5% of the maximum capacity.
Refuel the DEF / AdBlue® tank. (*1)
2
The engine output is limited to 50% (Lv.1: Level.1).
If operation is continued without refueling, the engine output
will be limited to Idle Status (Lv.2:Level.2).
The amount of remaining DEF/AdBlue® has decreased up
to 5% of the maximum capacity.
Refuel the DEF / AdBlue® tank. (*1)
2
The engine output is limited to 50% (Lv.1: Level.1).
If operation is continued without refueling, after 25 minutes,
the engine output will be limited to Idle Status (Lv.2:Level.2).
The amount of remaining DEF/AdBlue® has decreased up
to 5% of the maximum capacity.
3
The engine output will remain limited.
Refuel the DEF / AdBlue® tank. (*1)
The engine output is limited to Idle Status (Lv.2:Level.2).
Contains poor quality DEF/AdBlue® or other non-regulated
solutions.
After draining the tank, refuel with DEF/AdBlue® to reset the
1
warning system.
If operation is continued without refueling the DEF/AdBlue®
tank, after 60 minutes, the engine output will be limited to
50% (Lv.1:Level.1).
Contains poor quality DEF/AdBlue® or other non-regulated
solutions.
After draining the tank, refuel with DEF/AdBlue®. (*1)
2
The engine output is limited to 50% (Lv.1: Level.1).
If operation is continued without refueling the DEF/AdBlue®
tank, after 25 minutes, the engine output will be limited to
Idle Status (Lv.2:Level.2).
Contains poor quality DEF/AdBlue® or other non-regulated
solutions.
3
After draining the tank, refuel with DEF/AdBlue®. (*1)
The engine output is limited to Idle Status (Lv.2:Level.2).
Measures
DPF Parked
Regeneration
permit
inhibit
inhibit
inhibit
permit
inhibit
inhibit

Advertisement