Allen-Bradley 1398 ULTRA Plus Series Installation Manual page 138

Positioning drive module
Table of Contents

Advertisement

A-2
Specifications
1398 PDM-25, 50, 100, and
150
Publication 1398-5.1 — January 2000
1398-PDM-10, 20, 30, 75, and 150B Specifications (Continued)
Drive
1398
Module
PDM-10
(1 Φ )
Type
Relative
5% to 95% non-condensing
humidity
External Shunt Resistor P/N 9101-1079
Continuous
200 W
Shunt Power
Peak Shunt
6000 W
Power
1398-PDM-25, 50, 100, and 150 Specifications
Positioning
1398
Drive Module
PDM-25
Peak Output
25 amps
Current/Phase
Continuous
20 amps
Output
Current/Phase
Continuous
4 kW
Output
Power
Physical Specifications
Weight
15 lb
(5 kg)
Operating
32° to 122°F (0° to 50°C)
Temperature
Storage
-40° to 176°F (-40° to 80°C)
Temperature
Relative
5% to 95% non-condensing
humidity
External Shunt Modules
Continuous
200 W
Shunt Power
Peak Shunt
6000 W
Power
Power Supply
1398-PSM-50
Module
Line Voltage
100 to 240
Input
VAC
(3 Φ 50/60 Hz )
1398
1398
PDM-20
PDM-30
(1 Φ )
(1 Φ )
1398
1398
PDM-50
PDM-100
50 amps
100 amps
40 amps
50 amps
8 kW
10 kW
15 lb
15 lb
(5 kg)
(5 kg)
900W
10kW
1398-PSM-125
100 to 240 VAC
1398
1398
PDM-75
PDM-150B
(3 Φ )
(3 Φ )
1398
PDM-150
150 amps
65 amps
12 kW
21 lb
10 kg

Advertisement

Table of Contents
loading

Table of Contents