2Shudwru 7Huplqdo - Allen-Bradley 1398 ULTRA Plus Series Installation Manual

Positioning drive module
Table of Contents

Advertisement

Operator Terminal (screw terminal on back)
Pin and Signal names
Pin
RS-232
1
Tx
2
RxD
3
RTS
4
CTS
5
Common
Figure 3.27
ULTRA Plus PDM connects to the Operator Terminal
ULTRA Plus
Positioning Drive Module
(1398-PDM)
Pin
1
2
3 TxD
4
5 COMMON
6 SHIELD
7
8
9
$ MXPSHU FXVWRPHU VXSSOLHG PXVW EH LQVWDOOHG EHWZHHQ
IMPORTANT
SLQV  DQG  RI WKH 8/75$ 3OXV 2SHUDWRU 7HUPLQDO IRU
56 RSHUDWLRQ
Wire the ULTRA Plus PDM Components
.
Pin
6
7
8
9
10
9101-2205-XXX
ULTRA Plus to 1398-HMI-003
ULTRA Plus Operator Terminal cable
RxD
ULTRA Plus
Operator Terminal
(1398-HMI-003)
RS-422
TxA
TxB
RxA
RxB
Common
customer supplied
jumper
1 2 3 4 5 6 7 8 9 10
Publication 1398-5.1 — January 2000
3-43