Positioning drive module
Table of Contents

Advertisement

POWER SUPPLY MODULE
CIRCUIT BOARD
(COMPONENT SIDE)
W1 JUMPER SETTING
SHORTING JUMPER ACROSS
TOP 2 PINS (POSITION A)
SHORTING JUMPER ACROSS
BOTTOM 2 PINS (POSITION B)
(STANDARD SETTING)
Figure 3.8
Power Supply Module jumper location
EXTERNAL ENABLE INPUT IS SELECTED.
EXTERNAL CONNECTION IS REQUIRED
TO CONNECTOR TB1 SIGNALS ENABLE+
AND ENABLE-. REFER TO INSTRUCTION
MANUAL FOR SIGNAL SPECIFICATION
AND DETAILS OF OPERATION BEFORE
EXTERNAL ENABLE INPUT IS DE-ACTIVATED.
POWER SUPPLY MODULE IS ENABLED WHENEVER
INPUT POWER IS APPLIED AND NO POWER SUPPLY
MODULE FAULT CONDITIONS ARE DETECTED.
Wire the ULTRA Plus PDM Components
TB1
1
A
W1
4
B
SELECTS:
USING POSITION A.
DIAGNOSTIC
INDICATOR
LIGHTS
INTERFACE
CONNECTOR