Control; Setspoolposition; Setflow - Danfoss PVED-CL Technical Information

Hide thumbs Also See for PVED-CL:
Table of Contents

Advertisement

Technical Information

Control

SetSpoolPosition

SetFlow

PVED-CL Communication Protocol, version 1.38 Technical Information
Used to transmit the spool position set-point to the PVED-CL.
CAN message
Priority
PGN
XID
Occurrence
Modes
Sent by
Sent to
Data field
Bytes
Encoding
1, 2
UNSIGNED16
3, 4
SIGNED16
Used for transmitting a flow request to the PVED-CL. The flow request is converted to a spool position
with dead-band compensation. Use the SetFlow command for black-box testing the PVED-CL flow
characteristic in operational mode without knowledge to the actual dead-band settings.
Open-loop mode converts the flow request directly to the corresponding spool position with dead-band
compensation.
Closed-loop mode converts the flow request as for open-loop mode but adds the programmed closed
loop spool position offset (ClosedLoopXspOffset at parameter index 748) to the spool position. This
allows testing the valve output flow when used in Guidance mode.
CAN message
Priority
PGN
XID
Occurrence
Modes
Sent by
Sent to
Data field
Bytes
Encoding
1, 2
UNSIGNED16
11079551 • Rev BA • July 2014
6
61184
0x0FAD (MSB first)
when required
calibration
configuration tool
PVED-CL
Value/Range
Description
0x0FAD (MSB first)
extended message identifier (XID)
-1000 – 1000
requested spool position, reflects -7 – 7 mm spool
travel
6
61184
0x0FB8 (MSB first)
when required
calibration
configuration tool
PVED-CL
Value/Range
Description
0x0FB8 (MSB first)
extended message identifier (XID)
27