PVED-CL Communication Protocol, version 1.38 Technical Information
Data field (error identification data) (continued)
Bytes
Encoding
6–7
UNSIGNED16
Data field (timestamp)
Bytes
Encoding
1, 2
UNSIGNED16
3
UNSIGNED8
4
UNSIGNED8
5–8
UNSIGNED32
Data field (temperature)
Bytes
Encoding
1, 2
UNSIGNED16
3
UNSIGNED8
4
UNSIGNED8
5–6
SIGNED16
Used for clearing all error entries in the persistent error buffer.
CAN message
Priority
PGN
XID
Occurrence
Modes
Sent by
Sent to
Data field
Bytes
Encoding
1, 2
UNSIGNED16
11079551 • Rev BA • July 2014
Value/Range
Description
0 – 0xFFFE
– error code
0xFFFF
– wrong index or information not available
Value/Range
Description
0x0FB4 (MSB first)
extended message identifier (XID)
1 – 16
buffer index (the oldest error at index 1)
1
timestamp details
timestamp:
0 – 0xFFFFFFFE
– the value of a timer which starts counting upon
PVED-CL power-on, observed when the error
0xFFFFFFFF
occurred
– wrong index or no information available
Value/Range
Description
0x0FB4 (MSB first)
extended message identifier (XID)
1 – 16
buffer index (the oldest error at index 1)
2
temperature details
PVED temperature:
-50 – 150
– temperature in oC, observed when the error
150 – 450
occurred
– temperature sensor provided data, but was likely
-32768
to be damaged by being oveheated
– wrong index or no information available
6
61184
0x0FB5 (MSB first)
when needed
operational, reduced, calibration
configuration tool
PVED-CL
Value/Range
Description
0x0FB5 (MSB first)
extended message identifier (XID)