Hosts; Control Canisters - IBM V7000 Introduction And Implementation Manual

Flex system storage node
Table of Contents

Advertisement

Uses the IBM Flex System Enterprise Chassis for lower solution costs, thus eliminating
the need of external switches, cables, SFPs, fans, power supplies, for production
environments.
Note: Even though no external switches are required, the appropriate internal switch I/O
modules must be available in order for the necessary host interfacing to work.
IBM Flex System V7000 Storage Node consists of a set of drive enclosures. Control
enclosures contain disk drives and two control canisters and form an I/O group for its
management of additional internal and external storage. Expansion enclosures contain drives
and are attached to control enclosures.
The simplest use of IBM Flex System V7000 Storage Node is as a traditional RAID
subsystem. The internal drives are configured into RAID arrays and virtual disks created from
those arrays.
IBM Flex System V7000 Storage Node can also be used to virtualize other storage
controllers. An example of it is described in Chapter 7, "Storage Migration Wizard" on
page 283.
IBM Flex System V7000 Storage Node supports regular and solid-state drives. It can use IBM
System Storage Easy Tier to automatically place volume hot spots on better-performing
storage.

2.6.1 Hosts

A host system is an IBM Flex System compute node that is connected to IBM Flex System
V7000 Storage Node through a Fibre Channel connection or through an Ethernet connection
using either iSCSI or Fibre Channel over Ethernet (FCoE) connection through the switch
modules of the IBM Flex System. At the time of writing, attachment of external hosts to IBM
Flex System V7000 Storage Node is not supported.
Note: Direct attachment of AIX and SAS to IBM Flex System V7000 Storage Node
products is not supported at the time of writing this book.
Hosts are defined to IBM Flex System V7000 Storage Node by identifying their worldwide port
names (WWPNs) for Fibre Channel hosts. For iSCSI hosts, they are identified by using their
iSCSI names. The iSCSI names can either be iSCSI qualified names (IQNs) or extended
unique identifiers (EUIs).

2.6.2 Control canisters

IBM Flex System V7000 Storage Node can have two to eight hardware components called
control canisters that provide the virtualization of internal and external volumes, and cache
and copy services (Remote Copy) functions. Within IBM Flex System V7000 Storage Node a
pair of the control canisters are housed within a control enclosure. A clustered system
consists of a one to four control enclosures.
One of the control canisters within the system is known as the configuration node and it is the
canister that manages configuration activity for the clustered system. If this canister fails, the
system nominates another canister to become the configuration node. During initial setup, the
system will automatically select a canister for this role from the first control enclosure pair.
60