IBM V7000 Introduction And Implementation Manual page 537

Flex system storage node
Table of Contents

Advertisement

2
Scsi Port2 Bus0/Disk2 Part0
3
Scsi Port2 Bus0/Disk2 Part0
DEV#:
1 DEVICE NAME: Disk3 Part0 TYPE: 2145
SERIAL: 6005076000820005200000000000000D
============================================================================
Path#
Adapter/Hard Disk
0
Scsi Port1 Bus0/Disk3 Part0
1
Scsi Port1 Bus0/Disk3 Part0
2
Scsi Port2 Bus0/Disk3 Part0
3
Scsi Port2 Bus0/Disk3 Part0
PS C:\Program Files\IBM\SDDDSM>
6. The output provides information about the connected volumes. In our example, there are
two disks connected, Disks 2 and 3 for the Windows host, and four paths to each disk are
available (State = Open). This indicates that the SAN zoning has been set up correctly.
Open the Windows Disk Management window (Figure 12-6) by entering the command
mmc diskmgmt.msc from the Windows PowerShell command prompt. Figure 12-6 shows
the Disk Management window with the newly added Disk 3 presented, awaiting to be
allocated and used by Windows.
Figure 12-6 Windows Disk Management
OPEN
NORMAL
1021
OPEN
NORMAL
POLICY: OPTIMIZED
State Mode
Select
OPEN
NORMAL
OPEN
NORMAL
OPEN
NORMAL
OPEN
NORMAL
Chapter 12. Host configuration