Connection Brine - Danfoss DHP-A Installation Instructions Manual

Hide thumbs Also See for DHP-A:
Table of Contents

Advertisement

5.3

Connection brine

5.3.1
Connection brine DHP-H, DHP-H Opti, DHP-H Opti Pro, DHP-L, DHP-L Opti, DHP-L Opti Pro
7
2
3
4
1
3
Figure 27.
General connection diagram brine lines
5.3.2
Connection brine DHP-C
3
1
3
2
Figure 28.
General connection diagram brine lines
5.3.3
Connection brine DHP-A, DHP-A Opti
If the outdoor unit is installed higher than the heat pump a pressure tank with safety valve must be connected to
the outlet for bleeding.
If the outdoor unit is installed at the same level or lower than the heat pump, the accompanying plastic vessel can
be used. The upper part of the outdoor unit must then not exceed the fluid level in the vessel.
2
3 4 3
1
3
Figure 29.
General connection diagram, brine
lines
5
6
3
3
5
6
3
4
3
7
5
5
6
7
3
Symbol explanation
1
2
3
4
5
6
7
Symbol explanation
1
Brine in
2
Brine out
3
Shut-off valve (part of the filler cock)
4
Strainer
5
Safety valve (1.5 bar)
6
Bleed and expansion tank
7
Shut-off valve
Symbol explanation
8
1
Brine in
2
Brine out
3
Shut-off valve (part of the filler cock)
4
Strainer
5
Safety valve (1.5 bar)
6
Bleed and expansion tank
7
Shut-off valve
8
Pressure tank
Brine in
Brine out
Shut-off valve (part of the filler cock)
Dirt valve
Safety valve (1.5 bar)
Bleed and expansion tank
Shut-off valve
Installation instructions VMBMA1002 – 33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents