8.3.4
Parameter change-over
For up to 32 freely selectable parameters, the basic function "parameter change-over"
provides a change-over between four sets with different parameter values.
The value set to be used is selected binary-coded via the selection inputs
bSelectWriteValue_1 and bSelectWriteValue_2 of the SB LS_WriteParamList.
The writing of the parameter list is activated by a FALSE/TRUE edge at the bExecute
control input.
In the following example, the control inputs of the parameter change-over are linked to
the free parameters C00470/1...3 by parameterising the respective configuration
parameters (C00621/x):
[8-2]
Example: Linking the control inputs of the parameter change-over to "free" parameters
from Firmware V06.00 - DMS 1.1 EN - 11/2011
8400 StateLine C | Operating instructions
Adapting the application individually
Implementing more additional functions in the signal flow