Commissioning

Adapting the most important parameters to the drive task

6.3
Adapting the most important parameters to the drive task
The following short overview contains the most important parameters for a quick
commissioning.
 The following subchapters provide more detailed information on these parameters.
 A description of all parameters can be found in the software manual of the controller
and in the Engineer online help.
Parameter
C00011
C00059
C00015
C00016
C00022
C00120
C00142
C00173
C00034/1
C00026/1
C00027/1
C00010/x
C00012
C00013
C00039/1
C00039/2
C00039/3
C00105
C00114
C00118
C00434/1
C00435/1
C00006
C00018
C00021
C00019
C00036
C00106
C00910/1
C00910/2
Highlighted in grey = display parameter
34
Name
Appl.: Reference speed
Appl.: Reference frequency C11
VFC: V/f base frequency
VFC: Vmin boost
Imax in motor mode
Setting of motor overload (I²xt)
Auto-start option
Mains voltage
AIN1: Configuration
AIN1: Offset
AIN1: Gain
AIN1: Characteristic
Acceleration time - main setpoint
Deceleration time - main setpoint
Fixed setpoint 1
Fixed setpoint 2
Fixed setpoint 3
Decel. time - quick stop
DIx: Polarity
DOx: Polarity
O1U: Gain
O1U: Offset
Motor control
Switching frequency
Slip compensation
Auto-DCB: Threshold
DC braking: Current
Auto DCB: Hold time
Max. pos. output frequency
Max. neg. output frequency
L
Info/Lenze setting
1500 rpm
-
50.0 Hz
VFC = Voltage Frequency Control
1.60 %
depending on the device power
100.00 %
0x19 ≡ Controller inhibit when
• the controller is switched on (device on)
• Undervoltage
• Loading of the Lenze setting
0: "3ph 400V / 1ph 230V"
0: "-10...+10 v"
AIN1 = analog input
0.00 %
1.0000
see
parameter description
2.000 s
2.000 s
40.00 %
60.00 %
80.00 %
2.000 s
No inversion
DIx = digital inputs
No inversion
DOx = digital outputs
100.00 %
O1U = analog output
(voltage output)
0.00 %
6: "VFCplus:V /f linear"
2: "8 kHz var./drive-opt."
2.67 %
3 rpm
DCB = DC-injection braking
50.00 %
0.500 s
1000 Hz
1000 Hz