Environmental Specifications; Mechanical Specifications; Safety Specifications - AEMC 6550 User Manual

10kv and 15kv megohmmeters
Hide thumbs Also See for 6550:
Table of Contents

Advertisement

7.4 Environmental Specifications

■ Range of use
The relative humidity can significantly affect insulation. Take care not to make an insulation resistance measure-
ment if the temperature is below the dew point.
32° to 113°F (0° to 45°C); 0 to 90% RH
■ Specified domain of use
32° to 95°F (0° to 35°C); 0 to 75% RH
■ Storage (without the batteries)
-40° to 158°F (-40° to 70°C); 10 to 90% RH
■ Altitude: <2000m
■ Degree of pollution: 2

7.5 Mechanical Specifications

■ Dimensions: (LxWxH): 13.4 x 11.8 x 7.9" (340 x 300 x 200mm)
■ Weight: approximately 13.7 lb (6.2kg)

7.6 Safety Specifications

■ Electrical safety per: IEC-61010-1, IEC-61557 parts 1 and 2 (up to 10kV) or VDE 0413
■ Double insulation
■ Degree of pollution: 2
■ Voltage measurement category: 1000V CAT IV
■ Maximum voltage with respect to earth: 1000Vrms CAT IV
■ Maximum voltage between guard terminal G and the - terminal: 30Vrms
Megohmmeter Models 6550/6555
Shop for AEMC products online at:
ShopAEMC
www.
.ca
1.877.766.5412