(5) Remove the collar on each side of the blade
and install them to the new blade.
Notes: 1. During reassembly, attach the spring
securely. (Make sure that the frame side
should look as shown below.)
2. After installing the drum, apply patting
power to the drum and rotate it. Refer
to Sec. 11.3.1.
11.3.3
Toner full switch
(1) Disconnect a connector.
(2) Remove the switch.
1550/1560 CLEANER
Frame
Spring
11 - 6
Connector
Toner full switch
Blade
Collar