Thermostat, Thermistor And Brush - Toshiba 1550 Service Manual

Hide thumbs Also See for 1550:
Table of Contents

Advertisement

(5) Disconnect one connector and remove one
screw to take out the lamp holder (F).
Notes: 1. When replacing the lamp, don't touch it
with a bare hand.
2. Be careful so that the Toshiba mark is
on the front side.
12.3.3

Thermostat, thermistor and brush

(1) Remove the fuser unit.
(2) Remove the fuser guard.
(3) Remove the rear screw of the thermostat.
(4) Remove the holder unit (2 screws).
Thermostat:
Remove one screw to take it out.
Thermistor:
Remove one screw to take it out.
Brush:
Remove one screw to take it out.
1550/1560 FUSER
Thermostat
Thermistor
Brush
12 - 4
Lamp holder (F)
Holder unit
Thermistor
Thermostat
Mar. 1998 © TOSHIBA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1560

Table of Contents