You can change the durations and gaps anywhere in the message. Here is a
page with 1, 2, 3 sent at 50mS/50mS and A, B, C sent at 150mS/100mS with a
1-second pause between the two pages:
(PW) 15 9950 22 33 01 02 03 49 28 38 10 11 12 *
Note: The digit duration will now be at 150mS, and the gap will now be at
100mS, since those are the last parameters which were used.
You can use DTMF custom duration change characters and DTMF custom gap
characters if you have special requirements. In this example, we will generate
two pages. The first will be "1, 2, 3" at 160mS/110mS. Then we'll have a 5-
second pause, followed by "A, B, C" at 300mS/120mS
(PW) 15 9950 5016 5211 01 02 03 5550 5030 5212 10 11 12 *
Here's the explanation: 9950 = control character to generate a DTMF Page;
5016 = DTMF custom duration change, 16 x 10mS = 160mS; 5211 = DTMF
custom gap change, 11 x 10mS = 110mS; 5550 = DTMFcustom pause change,
10 x 100 mS = 5 seconds; 5030 = DTMF custom duration change, 30 x 10mS
= 300mS; and 5212 = DTMF custom gap change, 12 x 10mS = 120mS.