S-COM 7K Manual page 347

Microprocessor repeater controller
Table of Contents

Advertisement

Page
Command Name
16-8
Enable/Disable From-Start-of-
Transmission Timer for Rx3
17-1
Transmitter Functions
17-3
Select Courtesy Delay
17-4
Select Dropout Delay
17-5
Select Transmitter Timeout Timer
17-7
Reset Transmitter Timeout Timer
17-8
Enable/Disable Transmitter 1
17-8
Enable/Disable Transmitter 2
17-9
Key Transmitter (Timed)
17-10
Key Transmitter 1 (Untimed)
17-10
Key Transmitter 2 (Untimed)
17-11
Enable/Disable Tx1 Minimum Unkey
Delay
17-11
Enable/Disable Tx2 Minimum Unkey
Delay
Command Quick Reference
Form and Data Digit
(PW) 63 66 x *
0 = OFF (disabled)
1 = ON (enabled)
(PW) 32 xx *
(00-50) = 0.0-5.0 seconds
00 = 0.0 seconds
05 = 0.5 seconds
10 = 1.0 seconds
50 = 5.0 seconds ... etc.
(PW) 30 xx *
(00-50) = 0.0-5.0 seconds
00 = 0.0 seconds
05 = 0.5 seconds
10 = 1.0 seconds
50 = 5.0 seconds ... etc.
(PW) 40 xxx *
(001-546) = 0.1-54.6 minutes
000 = infinity
001 = 0.1 minute
030 = 3.0 minutes
546 = 54.6 minutes ... etc.
(PW) 10 *
(PW) 63 00 x *
0 = OFF (disabled)
1 = ON (enabled)
(PW) 63 22 x *
0 = OFF (disabled)
1 = ON (enabled)
(PW) 00 x yyy *
x = transmitter
1 = Tx1
2 = Tx2
y = duration
000 = cancel tx key
(001-546) = 0.1-54.6 minutes
001 = 0.1 minute
010 = 1.0 minute
100 = 10.0 minutes
546 = 54.6 minutes ... etc.
(PW) 63 41 x *
0 = cancel tx key
1 = key tx
(PW) 63 42 x *
0 = cancel tx key
1 = key tx
(PW) 63 31 x *
0 = OFF (disabled)
1 = ON (enabled)
(PW) 63 32 x *
0 = OFF (disabled)
1 = ON (enabled)
Programming Tables
Default
User
OFF
disabled
0.0
seconds
3.0
seconds
3.0
minutes
none
ON
enabled
ON
enabled
Tx1 and
Tx2 not
requested
to key
0
cancel tx
key
0
cancel tx
key
ON
enabled
OFF
disabled
A-47