S-COM 7K Manual page 174

Microprocessor repeater controller
Table of Contents

Advertisement

7K • Chapter 9
Acknowledgment: Sends OK
Errors:
Error
? err 1
? err 2
Default Condition: No setpoints exist.
Example:
To execute macro 1234 every hour, on the hour, every day, every month, enter
the following:
(PW) 28 00 1234 99 99 99 00 *
To execute macro 1234 every day at 6:15 AM, every month, enter the
following:
(PW) 28 01 1234 99 99 06 15 *
To execute macro 1234 at 10:30 AM on the weekend (Saturday and Sunday),
every month, enter the following:
(PW) 28 02 1234 99 33 10 30 *
To execute macro 1234 at midnight every Saturday in June, enter the
following:
(PW) 28 03 1234 06 40 00 00 *
To execute macro 1234 at noon on April 15th, enter the following:
(PW) 28 04 1234 04 15 12 00 *
To execute macro 1234 at 5:00 PM (17:00) on the first Thursday of every
month, enter the following:
(PW) 28 05 1234 99 45 17 00 *
It is not necessary to fill in each setpoint starting from 00. Unprogrammed
setpoints that cause gaps in the sequence will be ignored by the Scheduler.
You can minimize the number of programmed setpoints with creative
programming. For example, you may wish to execute a macro at 10:00 PM
each day of the week except Sundays. Instead of creating six setpoints for
Monday through Saturday, create just two: one for Saturday, and one for
weekdays.
9-4
Meaning
wrong number of digits entered
illegal digit entered
(Setpoint 00)
(Setpoint 01)
(Setpoint 02)
(Setpoint 03)
(Setpoint 04)
(Setpoint 05)

Advertisement

Table of Contents
loading

Related Products for S-COM 7K