Select ID Message Interval
Programs the maximum interval at which ID messages occur.
• Because of the polite nature of the identifier, an ID may be earlier if there is
a recent carrier drop. (Select ID Pending Interval For Tx1 and Tx2 on page
12-6.)
• Enter 3 digits, 005 to 300, representing 0.5 to 30.0 minutes.
• Repeaters in US amateur service must identify at least every 10 minutes.
Command Form:
Command
Select ID Message Interval for TX1 and TX2
Acknowledgment: Sends OK
Errors:
Error
? err 1
? err 2
Default Condition: ID Message Interval is 3.0 minutes
Examples:
To change the ID message interval to 4.5 minutes, enter the following
command:
(PW) 51 45 *
To change the ID message interval to (9.9 minutes), enter the following
command:
(PW) 51 99 *
Form
Data Digit
(PW) 51 xxx *
(005–300) =
(0.5–30.0) minutes
Meaning
wrong number of digits entered
illegal digit entered
Identifier
12-5