Operation Diagnostics
9.2.2 Monitoring correct operation via the signal
contact
Configuring the signal contact
U
V Select the Diagnostics:Signal Contact dialog.
V Select "Monitoring correct operation" in the frame "Mode Signal con-
tact", to use the contact for function monitoring.
V Select in the frame "Monitoring correct operation" the events which
you want to have monitored.
V For temperature monitoring set in the Basics:System dialog at the
end of the system data the temperature thresholds..
Signal contact display
U
You can view the signal contact state in three ways:
D
using the LED display,
D
using the web-based interface,
D
executing a query in the command line interface.
V Select the Basics:System dialog.
Fig. 48:
Alarm display
Layer 2 Enhanced with Layer 2 Professional
Release 1.0 10/05
Time of the oldest existing alarm
Cause of the oldest existing alarm
The blinking lamp indicates an alarm
9.2 Out-of-band signaling
139