Entering the IP parameters
2.7 System Configuration via
DHCP Option 82
As with the classic DHCP, on startup an agent receives its configuration data
according to the "BOOTP/DHCP process" flow chart
While the system configuration is based on the classic DHCP protocol on the
device being configured (see "System configuration via DHCP" on page 43),
Option 82 is based on the network topology. This procedure gives you the
option of always assigning the same IP address to any device which is
connected to a particular location (port of a Switch) on the LAN.
The installation of a DHCP server is described in the chapter
DHCP Server Option 82" on page
PLC
IP =
149.218.112.100
Fig. 15:
Application example of using Option 82
46

2.7 System Configuration via DHCP Option 82

160.
Switch (Option 82)
h H h H
h H
MICE
MAC address =
00:80:63:10:9a:d7
IP =
149.218.112.100
(see Fig.
MACH 3002
DHCP server
IP =
149.218.112.1
Layer 2 Enhanced with Layer 2 Professional
13).