Operation Diagnostics

9.2.1 Manual setting the signal contact

This mode gives you the option of remote switching each signal individually.
Application options:
D
Simulation of an error during SPS error monitoring.
D
Remote control of a device via SNMP, such as switching on a camera..
V Select the Diagnostics:Signal Contact 1/2 dialog.
V Select "Manual setting" in the "Mode Signal Contact" frame, to switch
the contact manually.
V Select "Opened" in the "Manual setting" frame to open the contact.
V Select "Closed" in the "Manual setting" frame to close the contact.
138
9.2 Out-of-band signaling
Layer 2 Enhanced with Layer 2 Professional
Release 1.0 10/05