Chapter 3 Keyboard
Press
PRG
Press PRG
1) The function code can not be modified itself, eg: actual detecting parameters,
running record parameters.
2) The function code can not be modified in the running status. It must be modified
in the stop status.

3-4-2.The way to read parameters in various status

In stop or run status, operate shift key
respectively. Parameter display selection depends on function code F6.01 (run
parameter 1), F6.02 (run parameter 2) and F6.03 (stop parameter 3).
In stop status, there are total 16 stop status parameters that can be set to display/not
display: set frequency, bus voltage, DI input status, DO output status, analog input AI1
voltage, analog input AI2 voltage, panel potentiometer input voltage, Actual count value,
Actual length value, PLC running step number, Actual speed display, PID settings, high-
speed pulse input frequency and reserve, switch and display the selected parameter by
pressing key orderly.
In running status,there are 5 running-status parameters:running frequency,setting
frequency,bus voltage,output voltage, output current default display, and other display
parameters: output power, output torque, DI input status, DO output status, analog input
AI1 voltage, analog input AI2 voltage, panel potentiometer input voltage, Actual count
value, Actual length value, linear speed, PID settings and PID feedback, etc, their
display depends on function code F6.01 and F6.02 switch and display the selected
parameter by pressing key orderly.
Inverter powers off and then powers on again, the displayed parameters are the
selected parameters before power-off.

3-4-3.Password settings

The inverter has password protection. When y0.01 become not zero, it is the
password and will be work after exit from function code modified status. Press PRG key
again, will display"----". One must input the correct password to go to regular menu,
otherwise, inaccessible.
To cancel the password protection function, firstly enter correct password to access
and then set y0.01 to 0.

3-4-4.Motor parameter auto tunning

Choose vector control, one must input the motor‟s parameters in the nameplate
accurately before running the inverter. PI9000 series frequency inverter will match the
motor‟s standard parameters according to its nameplate. The vector control is highly
depend on motor‟s parameters. The parameters of the controlled motor must be inputted
Press
ENTER
Press
PRG
Press
ENTER
to
confirm
to display a variety of status parameters
SHIFT
30
Press
ENTER
Flicker