Chapter 5 Function parameter
Fault output (fault
2
shutdown)
Frequency level
3
detection FDT1 output
4
Frequency arrival
Zero speed running
5
(shutdown without output)
Motor overload pre-
6
alarm
Inverter overload pre-
7
alarm
8
Set count value arrival
Specified count value
9
arrival
10
Length arrival
11
PLC cycle completed
Cumulative running
12
time arrival
Frequency being
13
limited
14
Torque being limited
15
Ready for operation
16
AI1> AI2
Upper limit frequency
17
arrival
18
Lower limit frequency
When the inverter occurs failure and
stops, and outputs ON signal.
Please refer to the instructions of function
code F7.23, F7.24
Please refer to the instructions of function
code F7.25
Outputs ON signal when the inverter is in
operation with output frequency (zero) Outputs
OFF signal when the inverter is in the sate of
stop
Before motor overload protection action,
it will output ON signal if it exceeds the pre-
alarm threshold. Please refer to function code
F8.02 to F8.04. for motor overload parameter
setting.
Outputs ON signal within 10s before
inverter overload protection action
Outputs ON signal when the count value
reaches the value set by E0.08.
Outputs ON signal when the count value
reaches the value set by E0.09. Please refer to
the instructions of E0 group for counting
function.
Outputs ON signal when the detected
Actual length exceeds the set length by E0.05.
Outputs a width of 250ms pulse signal
when simple PLC completes a cycle
Outputs ON signal when the inverter's
cumulative running time F6.07 exceeds the set
time by F7.21.
Outputs ON signal when the rated
frequency exceeds the upper limit frequency or
the lower limit frequency, and the output
frequency of inverter also reaches the upper
limit frequency or the lower limit frequency.
Outputs ON signal when the output torque
reaches the torque limit value and the inverter
is in the stall protection status under inverter
speed control mode
Outputs ON signal when the power supply
of the inverter main circuit and control circuit
has stabilized, and the inverter has not any fault
information and is in the runnable status.
Outputs ON signal when the value of
analog input AI1 is greater than the AI2 input
value,
Outputs ON signal when the operating
frequency reaches the upper limit frequency,
Outputs ON signal when the operating
112