Trigger Output Signal - Agilent Technologies 33250A User Manual

80 mhz function / arbitrary waveform generator
Hide thumbs Also See for 33250A:
Table of Contents

Advertisement

3
Chapter 3 Features and Functions
Triggering

Trigger Output Signal

A "trigger out" signal is provided on the rear-panel Trig Out connector
(used with sweep and burst only). When enabled, a TTL-compatible
square waveform with either a rising edge (default) or falling edge is
output from the rear-panel Trig Out connector at the beginning of the
sweep or burst.
Trig In / Out
FSK /Burst
• When the Internal (immediate) trigger source is selected, the function
generator outputs a square waveform with a 50% duty cycle from
the Trig Out connector at the beginning of the sweep or burst.
The period of the waveform is equal to the specified sweep time or
burst period.
• When the External trigger source is selected, the function generator
automatically disables the "trigger out" signal. The Trig Out connector
cannot be used for both operations at the same time (an externally-
triggered waveform uses the same connector to trigger the sweep
or burst).
• When the Bus (software) trigger source is selected, the function
generator outputs a pulse (>1 µs pulse width) from the Trig Out
connector at the beginning of each sweep or burst.
• Front-Panel Operation: After enabling sweeps or burst, press the
Trigger Setup softkey. Then select the desired edge by pressing the
Trig Out softkey.
• Remote Interface Operation:
OUTPut:TRIGger:SLOPe {POSitive|NEGative}
OUTPut:TRIGger {OFF|ON}
102
OUTPUT
+5 V
>1 µs
0 V
Rising edge shown.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents