Panasonic TH-55VF1HU Operating Informations page 87

Full hd lcd display
Table of Contents

Advertisement

Error response
Error message
"ERR1"
: Undefined control
command
"ERR2"
: Out of parameter
range
"ERR3"
: Busy status or
reception invalid
period
"ERR4"
: Timeout or reception
invalid period
"ERR5"
: Wrong data length
4 bytes
2. When [LAN control protocol] is set
to [Protocol 2].
Last
terminal
Communicates with the same protocol as that of a
symbol
Panasonic projector
When the WEB control administrator
privileges password has been set (Protect
mode)
(CR)
Connection method
0x0d
1
Obtain the display's IP address and the port number
(Default is 1024), and request connection to the
display.
The IP address and the port number can be obtained
from the following menus.
IP address:
1 byte
[Setup] → [Network settings] → [LAN setup] or
[Network status]
Port number:
[Setup] → [Network settings] → [LAN setup]
For more detail of the settings, see page 70, 70.
2
The display responds.
Response data
Data part Space
[NTCONTROL]
(ASCII
character
string)
9 bytes
Mode: 1 = Protect mode
3
Hash the following data with the MD5 algorithm, and
generate a 32-byte hash value.
[xxxxxx:yyyyy:zzzzzzzz]
xxxxxx :
WEB control administrator privileges user name
yyyyy :
Above administrator privileges user password
Default user name and password are as follows:
User name: admin1
Password: panasonic
zzzzzzzz :
8-byte random number obtained in step 2
Mode
Space
[ ]
[1]
[ ]
0x20
0x31
0x20
1 byte
1 byte
1 byte
Random
Last
number
terminal
part
symbol
[zzzzzzzz]
(CR)
(ASCII
0x0d
code
hex
number)
8 bytes
1 byte
87
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-55vf1hw

Table of Contents