Examples Of Wiring - BONFIGLIOLI ACTIVE CUBE Applications Manual

Frequency inverter
Hide thumbs Also See for ACTIVE CUBE:
Table of Contents

Advertisement

4.10

Examples of wiring

Example 1: Transmission of the reference frequency value without information about direction of
rotation
ACU Master in configuration 210
X210A
1
+20 V/180 mA
2
GND 20 V
S1IND, Safety function
STOA
3
S2IND Start clockwise operation
4
S3IND Start anticlockwise operation
5
+ -
B
S4IND Speed sensor 1, track B
6
A
S5IND Speed sensor 1, track A
7
M
X210B
1
S6IND Motor thermal contact
STOB
2
S7IND, Safety function
S1OUT
3
MFO1A Repetition frequency output
4
+10 V/4 mA
5
6
MFI1A
GND 10 V
7
To ensure correct operation, connect the GND terminals between the frequency inverters.
Overview of Parameter Setting Examples:
Master Settings
30
Configuration
420
Acceleration (Clockwise)
421
Deceleration (Clockwise)
490
Operation Mode (of speed sensor 1)
491
Division marks (of speed sensor 1)
550
Operation Mode
555
Repetition Freq. Operation
556
Division Marks (of Multifunctional output 1)
760
Operation Mode (of speed sensor monitoring)
766
Actual speed source
Slave Settings
30
Configuration
420
Acceleration (Clockwise)
421
Deceleration (Clockwise)
490
Operation Mode (of speed sensor 1)
491
Division marks (of speed sensor 1)
496
Operation Mode (of repetition frequency input) 62 – S6IND Double Evaluation pos.
497
Divider (of repetition frequency input)
685
Gear Factor Numerator
686
Gear Factor Denominator
689
Operation Mode (of electronic gear)
760
Operation Mode
766
Actual speed source
Note: The repetition frequency input receives the reference frequency value in single-channel mode.
The reference frequency value is transmitted, but not the direction of rotation. In this case the
direction of rotation must be set via the control terminals S2IND and S3IND at the slave.
09/08
09/08
HTL
Parameter
Application Manual Electronic Gear
Application Manual Electronic Gear
ACU Slave in configuration 215
X210A
1
+20 V/180 mA
2
GND 20 V
STOA
S1IND, Safety function
3
4
S2IND Start clockwise operation
5
S3IND Start anticlockwise operation
+ -
B
6
S4IND Speed sensor 1, track B
A
7
S5IND Speed sensor 1, track A
M
X210B
1
S6IND Repetition frequency input
STOB
S7IND, Safety function
2
3
S1OUT
MFO1A
4
5
+10 V/4 mA
+
6
MFI1A Analog signal reference gear factor
GND 10 V
7
-
Setting/Selection
210 – speed-controlled field oriented control
5 Hz/s
5 Hz/s
4 – Quadruple Evaluation
Division marks of the master speed sensor
3 – Repetition Frequency
3 – Freq. Speed Sensor 1
1024
2 – Error
1 – Speed sensor 1
215 – speed-controlled field-oriented control
with electronic gear
10 Hz/s
10 Hz/s
4 – Quadruple Evaluation
Division marks of the slave speed sensor
1024
1
1
1 – Fixed
2 – Error
1 – Speed sensor 1
HTL
25
25

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACTIVE CUBE and is the answer not in the manual?

Questions and answers

Table of Contents