Note: Parameter
S
4.9.2
For the function of the electronic gear via the repetition frequency, the following set-
tings (examples) can be made at the frequency inverter of the Slave drive.
Different values for parameters
Slave and
in different speeds of the Master drive and the Slave drive if the number of pole pairs
of the motors is the same.
09/08
09/08
Select an operation mode for parameter
Operation Mode "3 – Frequency Speed Sensor 1", for the Master drive with speed
sensor feedback. In this operation mode, the speed of the Slave drive follows the
speed of the Master drive at the highest accuracy. Depending on the application,
you can also choose another operation mode for
Repetition Frequency Mode
modules with resolver interface EM-RES. The number of division marks is set
permanently to 1024.
The expansion module is equipped with a two-channel repetition frequency
output for push-pull operation (TTL).
Set the value for parameter
quency at the repetition frequency output. This is the number of pulses per motor
revolution for the repetition frequency. The pulse duration depends on the motor
speed. By default, this parameter is set to 1024. When making the settings, take
the frequency limit of the frequency output of 150 kHz into account. The maxi-
mum value S
which can be set for parameter
max
150
000
Hz
=
max
absolute
frequency

Frequency Inverter as Slave

If not done yet after the commissioning, select one of the configurations with
electronic gear for parameter
controlled field-oriented control with electronic gear". Depending on the applica-
tion, another configuration with electronic gear can be selected, too.
Operation Mode
For parameter
frequency and the type of evaluation, e.g. "62 – S6IND Double Evaluation pos.".
Since the rated speed decreases when the number of pole pairs is higher (n~1/p),
different speeds may result if the Master and Slave have the same reference fre-
quencies. Adjust the values for parameters
cy input of the Slave and
of the Master according to the number of pole pairs of the motors in order to ob-
tain the same speeds for the Master drive and the Slave drive. Different speeds
can be realized by setting the gear factor, as described in chapters "Setting a
Fixed Gear Factor" and "Setting a Variable Gear Factor".
Division Marks
Application Manual Electronic Gear
Application Manual Electronic Gear
Repetition frequency Mode
555 is not available for the expansion
Division Marks
556 according to the required fre-
Division
Marks
;
556
Configuration
30, e.g. Configuration "215 – speed-
496, select the digital input for the repetition
Divider
Division Marks
556 of the repetition frequency output
Divider
497 of the repetition frequency input of the
556 of the repetition frequency output of the Master result
Repetition Frequency Mode
Division Marks
556 is:
motor
speed
150
kHz
Gear
Factor
497 of the repetition frequen-
555, e.g.
555.