Configuration 515 – field-oriented control of a synchronous
machine with electronic gear and position control
Note:
Configuration 516 – field-oriented control of a synchronous
machine with electronic gear and index control
Note: For the operation of a synchronous machine, an expansion module for eva-
09/08
09/08
X210A
1
+20 V/180 mA
2
GND 20 V
STOA
3
S1IND
4
S2IND
5
S3IND
B
6
S4IND
A
7
S5IND
M
X210B
1
S6IND
S7IND
STOB
2
-
+
S1OUT
3
-
+
V
MFO1A
4
+10 V/4 mA
5
+
6
MFI1A
GND 10 V
7
-
For the operation of a synchronous machine, an expansion module for
evaluating a resolver is required. This functionality is available with the
modules of the EM-RES series.
X210A
1
+20 V/180 mA
2
GND 20 V
STOA
3
S1IND
S2IND
4
5
S3IND
B
6
S4IND
A
7
S5IND
M
X210B
1
S6IND
S7IND
2
STOB
-
+
S1OUT
3
-
+
MFO1A
V
4
+10 V/4 mA
5
6
MFI1D
GND 10 V
7
luating a resolver is required. This functionality is available with the modules
of the EM-RES series.
Application Manual Electronic Gear
Application Manual Electronic Gear
Control terminal X210A
X210A.1
Supply voltage +20V
X210A.2
Ground 20 V
X210A.3
Safety function, digital input STOA
X210A.4
Start of clockwise operation
X210A.5
Start of anticlockwise operation
X210A.6
Reference value electronic gear
at speed sensor 1 input, track B
X210A.7
Reference value electronic gear
at speed sensor 1 input, track A
Control terminal X210B
X210B.1
Motor thermal contact
X210B.2
Safety function, digital input STOB
X210B.3
Operating message
X210B.4
Analog signal of actual frequency
X210B.5
Supply voltage +10V
X210B.6
Analog signal reference gear factor
X210B.7
Ground 10 V
Control terminal X210A
X210A.1
Supply voltage +20V
X210A.2
Ground 20 V
X210A.3
Safety function, digital input STOA
X210A.4
Index signal Master
X210A.5
Index signal Slave
X210A.6
Reference value electronic gear
at speed sensor 1 input, track B
X210A.7
Reference value electronic gear
at speed sensor 1 input, track A
Control terminal X210B
X210B.1
Motor thermal contact
X210B.2
Safety function, digital input STOB
X210B.3
Operating message
X210B.4
Analog signal of actual frequency
X210B.5
Supply voltage +10V
X210B.6
Index controller release
X210B.7
Ground 10 V