Dialer Programming ( ∗ 40 – ∗ 50)
FIELD
TITLE and DATA ENTRIES
PABX Access Code
*40
Enter up to 6 digits if PABX is needed to
access an outside line. Do not fill unused
spaces.
0–9, # + 11 for '∗', # + 12 for '#', # + 13 for a
pause (2 seconds)
Primary Phone No.
*41
Enter up to 20 digits. Do not fill unused
spaces.
0–9, # + 11 for '∗', # + 12 for '#', # + 13 for a
pause (2 seconds)
Secondary Phone No.
*42
Enter up to 20 digits. Do not fill unused
spaces.
0–9, # + 11 for ' ', # + 12 for '#', # + 13 for a
pause (2 seconds)
Partition 1 Subscriber ID No.
*43
Enter digits 0–9; # + 15 for F.
Partition 2 Subscriber ID No.
*45
Enter digits 0–9; # + 15 for F.
Phone System Select
*47
If Central Station Receiver is not on WATS
line: 0 = Pulse Dial; 1 = Tone Dial
If Central Station Receiver is on WATS line:
2 = Pulse Dial; 3 = Tone Dial
Report Format
*48
5 = CID using 10-digit account number
7 = CID using 4-digit account no.
#14 = CID 4-digit account no. with shutdown
#15 = CID 10-digit account no. w/shutdown
Split/Dual Reporting
*49
0 = disable (Backup report only).
1 - 5 (see table to right)
15-Second Dialer Delay (Burglary)
*50
0 = no dialer delay
1 = 15-second delay
Misc. Fault Delay Time
*53
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
EXPLANATION
To clear entries from field, press ∗40∗. If fewer than 6 digits need to
be entered, exit by pressing [∗], which advances to the next field.
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number (e.g., 42). To clear entries from field, press ∗41∗.
NOTE: Backup reporting (in which 8 calls are made to the secondary
phone number if no kissoff is received after 8 attempts to the
primary number) is automatic only if there is a secondary phone
number (field ∗42).
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number (e.g., 43). To clear entries from field, press ∗42∗. See backup
reporting note for field ∗41.
Enter 4 or 10 digits, depending on report format selection in field
*48. To clear entries from field, press ∗43∗. Automatically puts same
entries into field *45.
Enter 4 or 10 digits, depending on report format selection in field
*48. To clear entries from field, press ∗45∗.
Select the type of telephone service.
Select for primary and secondary phone numbers either 4-digit or 10-
(Primary/Secondary)
digit Contact ID account number format, or 4-digit/10-digit with
shutdown capability.
1 = alarms, restore, cancel
2 = all except open/close, test
3 = alarms, restore, cancel
4 = all except open/close, test
5 = all
Provides delay of "BURGLARY ALARM" report to the central
station, which allows time for the subscriber to avoid a false alarm
transmission. This delay does not apply to zone type 24 alarms,
which are always sent as soon as they occur.
UL installations must be 0 (no delay).
Used with zones assigned to zone type 25 and/or zones assigned to a
configurable zone type with fault delay on. This field lets you select a
zone response time of 15 seconds to 15 min. It can be assigned to
#+13 = 10 min
#+14 = 12 min
zones with sensors designed to provide a trouble indication when an
#+15 = 15 min
oil tank is low, or other similar application for critical condition
monitoring where a non-alarm response is desired.
To Primary No.
To Secondary No.
others
open/close, test
all
all
all
4-3