Restore Report Codes ( ∗ 70- ∗ 76) - ADT Safewatch Pro 3000 Installaton Manual

Hide thumbs Also See for Safewatch Pro 3000:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Trouble Report Code
*60
0 = no report
1st digit non-zero = send report
Bypass Report Code
*61
0 = no report
1st digit non-zero = send report
AC Loss Report Code
*62
0 = no report
1st digit non-zero = send report
Low Bat Report Code
*63
0 = no report
1st digit non-zero = send report
Test Report Code
*64
0 = no report
1st digit non-zero = send report
Open Report Code
*65
0 = no report
1st digit non-zero = send report
Arm Away/Stay Report Code
*66
0 = no report
1st digit non-zero = send report
RF Trans. Low Batt. Report Code
*67
0 = no report
1st digit non-zero = send report
Cancel Report Code
*68
0 = no report
1st digit non-zero = send report
Restore Report Codes ( ∗ 70– ∗ 76)
FIELD
TITLE and DATA ENTRIES
Alarm Restore Report Code
*70
0 = no report
non-zero = send report
Trouble Restore Report Code
*71
0 = no report
1st digit non-zero = send report
Bypass Restore Report Code
*72
0 = no report
1st digit non-zero = send report
AC Restore Report Code
*73
0 = no report
1st digit non-zero = send report
Low Bat Restore Report Code
*74
0 = no report
1st digit non-zero = send report
RF Xmtr Low Batt. Restore Code
*75
0 = no report
1st digit non-zero = send report
Test Restore Report Code
*76
0 = no report
1st digit non-zero = send report
EXPLANATION
This will be sent if a zone has a trouble condition.
This will be sent when a zone is manually bypassed.
Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no "AC RESTORE"
report.
This will be sent when a low-battery condition exists in the system's
standby battery.
This is sent periodically to test that the communicator and phone
lines are operational. Frequency of report is set using Scheduling
mode (event 11).
This is sent upon disarming of the system in the selected partitions.
This option allows for independent programming of Away and Stay
reports for each partition, including the common lobby.
NOTE: "OPEN" reports are not sent if the associated closing report
is not enabled.
This is sent in the event that a wireless transmitter low-battery
condition exists.
This is sent upon disarming of the system after an alarm condition
was reported.
EXPLANATION
This is sent when the zone that caused an alarm is restored to its
non-faulted condition.
This is sent when a trouble in a zone is restored
This is sent when a zone that has been bypassed is unbypassed.
This is sent when AC power has been restored after an AC power
outage.
This is sent when a system low-battery condition is restored to
normal.
This is sent when a transmitter that previously sent in a "LOW
BATTERY" message has sent a message indicating it no longer has a
low-battery condition.
This is sent when the Test mode is exited.