Sounder (Bell) Connections

1. Make sounder connections to alarm output terminals
3 (+) and 4 (–).
For supervised output, continue with steps 2 and 3.
2. Cut the red Bell Supervision Jumper located above
terminals 2 and 3 on the control board.
3. Connect a 2k ohm resistor across the terminals of the
last sounder.
TERMINALS ON
CONTROL BOARD
4
ALARM
OUTPUT
TERMINALS
3
2
CUT RED JUMPER ON CONTROL
BOARD TO ENABLE BELL
(SOUNDER) SUPERVISION.
Figure 5. Sounder Wiring (Supervised)

Wiring the AC Transformer

1321 Transformer:
Connect the 1321 Transformer to terminals 1 and 2 on
the control board. See wiring table at right for wire gauge
to use.
4300/1321X10 Transformer
(required if using Powerline Carrier devices)
1. Splice one end of a 3-conductor cable to the wire ends
of the SA4120XM-1 Cable.
2. Connect the SA4120XM-1 cable plug to the 8-pin
connector on the control (see the Summary of
Connections diagram for location of the 8-pin
connector).
3. Connect the other end of the 3-conductor cable to the
4300/1321X10 Transformer, as shown.
1321X10 TRANSFORMER
AC
AC
SYNC COM
1
2
3
4
1
2
CONTROL
BOARD
TERMS.
2-4
EXTERNAL ALARM
SOUNDER
_
_
OBSERVE
POLARITY
+
+
IF BELL SUPERVISION IS ENABLED IN FIELD *91,
AND RED JUMPER ON CONTROL BOARD IS CUT,
CONNECT A 2000 OHM RESISTOR ACROSS THE
EXTERNAL SOUNDER AS SHOWN BY THE
DOTTED LINE.
DO NOT CONNECT THE RESISTOR AT THE
ALARM OUTPUT TERMINALS THEMSELVES!
8-PIN TRIGGER CONNECTOR
1
3
4
5
6
7
8
DATA
5
Figure 6. Connections of 1321X10 and 4300 Transformer to the Control Board
Notes
This control complies with NFPA requirements for
temporal pulse sounding of fire notification appliances.
Temporal pulse sounding for a fire alarm consists of:
3 pulses – pause – 3 pulses – pause – 3 pulses–etc..
• The 12VDC sounder output activates when an
alarm occurs.
• Total current drawn from this output cannot
exceed 2 amps
(going beyond 2 amps will overload the power
supply, or may cause the electronic circuit
protecting the sounder output to trip).
• You must install a battery, since the battery
2000
supplies this current.
OHM
EOL
RESISTOR
U L
• Use only UL Listed sounding devices for UL
installations.
• The total current drawn from the alarm output
and the auxiliary power output, combined,
cannot exceed 700 mA. In addition, the
sounding device must be a UL Listed audible
signal appliance rated to operate in a 10.2-13.8
VDC voltage range, and must be mounted
ADT3000-011-V0
indoors.
Notes
• Use caution when wiring the transformer to the
control to guard against blowing the transformer
fuse (the fuse is non-replaceable).
• Wiring to the AC transformer must not exceed
250 feet using 16 gauge wire. The voltage
reading between terminals 1 and 2 of the
control must not fall below 16.5VAC or an "AC
LOSS" message will be displayed.
• Do not plug the transformer into the AC outlet
while making any wiring connections to the
control. As a safety precaution, always power
down the control when making such connections.
Wiring Table
Distance from control
Up to 50 feet
50–100 feet
100-250 feet
4300 TRANSFORMER INTERFACE
OR
EARTH
GROUND
AC
AC
1
2
3
SA412OXM-1
CABLE
1
25
2
TERMINALS ON
CONTROL BOARD
Wire Gauge
# 20
# 18
# 16
8-PIN TRIGGER CONNECTOR
1
3
4
SYNC
DATA
COM
4
5
6
5
6
7
8
SA412OXM-1
CABLE
ADT3000-004-V1