Specifications & Accessories; Security Control; Compatible Devices - ADT Safewatch Pro 3000 Installaton Manual

Hide thumbs Also See for Safewatch Pro 3000:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

SECURITY CONTROL

1. Physical: 12-1/2" W x 14-1/2" H x 3" D (318mm x 368mm x 76mm)
2. Electrical:
VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No. 1321 (in U.S.A.)
RECHARGEABLE BACKUP BATTERY: 12VDC, 4AH (sealed lead acid type). Charging
ALARM SOUNDER: 12V, 2.0 Amp output can drive 12V BELLS or can drive one or two
AUXILIARY POWER OUTPUT: 12VDC, 600mA max.
Note: For UL installations, Alarm Sounder plus Auxiliary Power currents should not
exceed 700mA total.
STANDBY TIME: (see Section 12: Final Power-Up)
FUSE: Battery (3A) No. 90–12
3. Communication:
FORMAT SUPPORTED:
LINE SEIZE: Double Pole
RINGER EQUIVALENCE: TBD
FCC REGISTRATION No.: TBD
4. Maximum Zone Resistance: Zones 1–8 = 300 ohms excluding EOLR standard zones

COMPATIBLE DEVICES

Touchpads:
Wireless Receivers: 5881L/5882L: accepts up to 8 transmitters
Zone Expansion:
Relay Module:
Phone Modules:
Long Range Radio
Specifications & Accessories
702 (series connected) self-contained 20-watt sirens. Do not connect
two 702s in parallel.
Ademco Contact ID Reporting, 10 characters/sec., DTMF (TouchTone) Data Tones,
1400/2300Hz ACK, 1400Hz KISSOFF.
6137B, 6139B
5881M/5882M: accepts up to 16 transmitters
5881H/5882H: accepts up to system maximum transmitters
5800TM Transmitter Module (used with 5827BD Wireless 2-Way Touchpad)
4219 WIRED EXPANSION MODULE
4229 WIRED EXPANSION/RELAY MODULE
4204 RELAY MODULE
4285 PHONE MODULE
4286VIP PHONE MODULE
7835C/7845C
S E C T I O N
Voltage: 13.8VDC.
1 4
14-1

Hide quick links: