Miscellaneous System Fields - ADT Safewatch Pro 3000 Installaton Manual

Hide thumbs Also See for Safewatch Pro 3000:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Pager 3 Phone No.
*166
Enter up to 20 digits
Pager 3 Characters
*167
Enter up to 16 characters
Pager 3 Reports
*168
see pager 1 reports, field *162 for entries,
except use zone list 11.
Pager 4 Phone No.
*169
Enter up to 20 digits
Pager 4 Characters
*170
Enter up to 16 characters
Pager 4 Reports
*171
see pager 1 reports, field *162 for entries,
except use zone list 12.
Pager Delay Option for Alarms
*172
0 = none
1 = 1 minute

Miscellaneous System Fields

RF Reporting Options
*173
1 = RF Tamper reports during disarm (1=
enable, 0 = disable)
2 = RF button types send low battery
reports (1= enable, 0 = disable)
8 = RF low battery reports delayed (1=
delayed 28 days, 0 = immediate)
Clean Me Option
*174
0 = disable
1 = enable
3 - Clean Me reports delayed for 28 days
Up And About Time
*175
0 = none;
1-15 = 1 to 15 hours respectively
Lack Of Usage Option
*176
1-15 weeks
Device Duration 1, 2
*177
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Single Zone Bypass
*180
0 = disable
1 = enable
50/60 Hz AC Operation
*181
0 = 60 Hz
1 = 50 Hz
EXPLANATION
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number. To clear entries from this field, press ∗166∗.
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗167∗.
Enter the types of reports to be sent to pager 3 for each partition.
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number. To clear entries from this field, press ∗169∗.
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗170∗.
Enter the types of reports to be sent to pager 4 for each partition.
This field determines the delay of alarm reports to the pager. This
gives the Central Station enough time to verify the alarm report that
2 = 2 minutes
it received, before the dialer attempts to dial the pager.
3 = 3 minutes
NOTE: The delay does not reset for new alarms occurring while an
existing pager delay is in progress.
This delay is for ALL pagers in the system.
Example: .Entering "10" (8 + 2) will enable button-type transmitters
to send low battery reports, and delay all low battery reports for 28
days.
This is a maintenance feature for ESL 2-wire smoke detectors
on Zone 1. If used, this option limits the number of smoke detectors to
a maximum of 10, rather than 16. To enable the "clean me" feature, a
time response setting of "3" (1.2 seconds) must be entered in ∗56 Zone
Programming for zone 1.
This feature requires programming of an Up and About schedule (see
Scheduling section for details). If no zones are faulted or no key is
pressed within the selected time period during a scheduled Up and
About time window, a report is sent to the central station. This can
serve as a safety feature for elderly, infirm, or disabled persons.
If the control is not armed within the selected time period, a report is
sent to the central station.
These entries set the duration for output action options 5 (duration
1) and 6 (duration 2) programmed in ∗80 Output Function
Programming.
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
If enabled, users can bypass only one zone when arming the system.
Select the type of AC power applied to the control.
4-9