ADT Safewatch Pro 3000 Installaton Manual page 35

Hide thumbs Also See for Safewatch Pro 3000:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Option Selection
*91
0 = none
1 = Bell Supervision†
4 = using Audio Alarm Verification (AAV) unit
8 = Enable Exit delay restart ††
Phone Line Monitor Enable
*92
1st Digit Entry–Timeout:
0 = disabled
1-15 = 1 minute to 15 minutes respectively
(2 = 2 minutes, 3 = 3 minutes, etc.)
2nd Digit Entry–Display/Sound:
0 = touchpad display only when phone line
is faulted.
1 = touchpad display plus touchpad trouble
sound when line is faulted. Each
partition turns off its own trouble sound.
No automatic timeout.
2 = Same as "1" plus programmed output
device STARTS. If either partition is
armed, external sounder activates.
External sounder will be turned off by
normal bell timeout, or by security code
plus OFF from either partition (it does
not have to be the one that was armed).
No. of Reports In Armed Period
*93
per Zone (Swinger Suppression)
0 = unlimited number of reports
1 = 1 report per zone per armed period
2 = 2 reports per zone per armed period
Download Phone Number
*94
Enter up to 20 digits as follows: 0–9, # +11
for "∗", # + 12 for "#", # + 13 for a pause.
Ring Detection Count For
*95
Downloading
0–15 = number of rings before control picks
up phone line .
EXPLANATION
Select the desired options by adding the values of each desired option.
Multiple choice example: for both AAV and Exit delay restart†, enter
# + 12
(4 + 8); for all (1 + 4 + 8), enter # + 13.
UL installations cannot use AAV.
† If bell supervision is selected, the red jumper on the PC board must
be cut.
††"Exit Delay Restart" option allows use of the [∗] key to restart the
exit delay at any time when the system is armed STAY or INSTANT.
This will then allow the user to let someone in through an entry/exit
door, without having to disarm the system and then re-arm it again.
IMPORTANT: AAV should not be used when Paging or Alarm
Reports are being sent to a Secondary number. If this is done, the
call to the Secondary number by the communicator after the alarm
report will prevent the AAV from taking control of the telephone line,
and the AAV "Listen in" session cannot take place.
First digit: Sets the length of time a phone line fault must remain
after detected before the second digit option is activated.
Second digit: Selects the desired phone line fault response.
Option 2 may be used even if a relay unit or Powerline carrier device
is not connected to the control.
Programmed Output Device must either be programmed to be
STOPPED in field ∗80 or STOPPED by entry of [security code] + [#]
+ 8 + device number. Partition in ∗80 should be set to "0," for STOP.
This option can be used to limit the number of alarm/alarm restore
messages per zone sent to the central station in an armed period.
UL installations must be 0 (unlimited reports).
Enter the phone number of the downloading computer.
Do not fill unused spaces. End field by entering ∗. To clear entries
from field, press ∗94∗.
Refer to the chart below and program this field accordingly.
phone
answer
down-
module
machine
loading
yes
no
no
yes
yes
no
yes
no
yes
yes
yes
yes
no
no
no
no
yes
no
no
no
yes
no
yes
yes
NOTE: If "15" is entered to bypass an answering machine, and a 4285 or 4286
Phone Module is included in the system, you should note the following:
When calling in from an off-premises phone, the user should make the
initial call, allow 1 or 2 rings only, then hang up. The user should then
call again. The phone module will now seize the line, and 2 long tones
sound, followed by the usual voice prompt for the access code. If this
procedure is not followed, phone module operation will not be possible.
Set field ∗95 to...
1-14 (not 0)
higher than number of rings set on
answer machine (e.g., if ans.
machine is 4 rings, set this field to
5). This allows access to the phone
module if the ansewr machine is
turned off.
1-14 (not 0)
15 (bypasses answer machine)
0
0
1-14
15 (see note below)
4-7