Features and Installation Highlights

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
The ADT Safewatch Pro 3000 control is a 2-partition control with the following major features:

Capabilities

• 2 partitions; can protect two independent areas, as if each area had its own separate control.
• Common zone option allows either partition to arm, while leaving a common area (ex. lobby or
foyer) disarmed for access into the other partition.
• 48 protection zones plus 16 keyfob zones (total 64 zones) as follows:
-- 8 basic hardwired zones
-- Up to 40 additional wired zones using up to 5 4219/4229 modules.
-- Supports up to 4 configurable zone types
• Up to 48 Security Codes, each with separate authority levels and partition access
• Up to 3 programmable panic key functions; reported separately by partition, distinguished by
subscriber ID number
• Communication Format: Ademco Contact ID
• Downloading via an IBM compatible computer, Compass downloading software, and a compatible
HAYES modem specified by Ademco.

Functions

• Single-button arming feature: Can use up to 2 dedicated keypad keys on Custom English Display
touchpads to arm the system AWAY or STAY
• Scheduling, which can control devices and/or auto-arm/disarm the system
• Up to 4 keypad macros, which can be activated by wired touchpads
• Paging feature allows certain system conditions to be reported to up to 4 pager phone numbers; can
use a dedicated key on touchpads to send a signal to a pager
• Built-in Telephone Line Monitoring option can monitor the telephone line voltage and can cause a
local display, or a display and trouble/alarm sound.
• Event Logging records up to 100 selected events in a history log (control and readout from the log
is done via Ademco Compass Downloader software or installer/master code at Touchpad).
• Zone descriptors for all zones (useful only when using Custom English display touchpads and/or
the 4285/4286 Phone Module).
• Optional bell supervision detects external sounder wiring short or open; causes a trouble condition,
keypad display, and sends a report to the central monitoring station, if enabled.
• Optional RF jam detection for wireless systems detects a condition that may impede proper RF
reception (i.e., jamming or other RF interference); causes keypad display, and sends a report to the
central monitoring station (if trouble reporting is enabled).