Adt Standard Programming Form - ADT SA10ADTEG Programming Manual

For standard controls. safewatch pro & security manager.
Hide thumbs Also See for SA10ADTEG:
Table of Contents

Advertisement

Local programming requires the use of a 2-line Custom English touchpad connected to the touchpad
terminals on the control.
Values shown in boxes are "Standard" ADT defaults.
Field
Function
–––––
––––––––––––––––––––––––––––
SYSTEM SETUP ( 20- 27)
20 INSTALLER CODE
21 QUICK ARM ENABLE
22
RF SYSTEM TYPE
23 FORCED BYPASS FUNCTION
24 RF HOUSE ID CODE
25 OUTPUT RELAY MODULE
26 VOICE MODULE ACCESS CODE
27 OUTPUT TO LONG RANGE RADIO
ZONE SOUNDS AND TIMING ( 28- 39)
28 SINGLE ALARM SOUNDING/ZONE
29 FIRE SOUNDER TIMEOUT
30 ALARM BELL TIMEOUT
36 EXIT DELAY
37 ENTRY DELAY#1
38 ENTRY DELAY#2
39 AUDIBLE EXIT WARNING
DIALER PROGRAMMING ( 40- 50)
40 PABX ACCESS CODE
41 PRIMARY PHONE#
42 SECONDARY
PHONE #
43 SUBSCRIBER ACCT No.
45 PHONE SYSTEM SELECT
† Entry of a number other than the one specified will give unpredictable results.
STANDARD PROGRAMMING FORM
Programming Selections
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
6
1
0
1
0
0
0
0
0
0
1
6
4
1
1
In fields 40, 41, 42, enter up to the number of digits shown. Do not fill unused
spaces. Enter 0-9; #+11 for ' '; #+12 for '#'; #+13 for a pause.
pressing
(and press 41, if entering next field). To clear entries from field, press
If fewer than 20 digits entered, exit by pressing
press
41 .
If fewer than
20 digits entered, exit by pressing
press
42 .
Enter 0 as the first digit of a 4-digit account number for Nos. 0000–0999. End field by pressing
next field #).
Examples: For Acct No. 1234 , enter:
3
If Cent. Sta. IS NOT on a WATS line: 0 = Pulse Dial;
If Cent. Sta. IS on a WATS line:
ADT
3
2
1
4 digits, 0-9.
0 = no; 1 = yes.
0 = none; 1 = 5800 (5881 Type RF Receiver) with no RF jam detection; 4 = 5800
with RF jam detection.
0 = none; 1 = bypass open zones.
0
Enter 01-31 if a 5827 or 5827BD Touchpad is used in a 5800 RF system.
0 = none; 3 = 4204.
0
1st digit: Enter 1–9; 2nd digit: Enter only #+11 for ' ', #+12 for '#'.
0 in either position = disabled.
0 = no; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field
also be sent via LRR.
0 = no; 1 = yes.
0 = fire sounder timeout; 1 = no fire sounder timeout.
0 = none; 1= 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min.
0
00–99 seconds.
5
00–99 seconds.
0
00–99 seconds.
0 = no; 1 = yes.
E
nter up to 6 digts. If fewer than 6 digits entered, exit by
(and press 43, if entering next field). To clear entries from field,
(and press 43, if entering next field). To clear entries from field,
Enter 0-9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F.
For Acct No. B234, enter:
2 = Pulse Dial ;
– 3 –
1
2
3
#+11
2
3
1 = Tone Dial
3 = Tone Dial
47) will
40 .
(and press
4
4