Connecting Relay Modules

1. Mount either remotely or in the control panel.
2. Connect to control's touchpad terminals using the
connector harness supplied with the module. Use
standard 4-conductor twisted cable for long wiring
runs.
3. Set each module's device address according to the
table at right.
4. Connect the desired field wiring to the unit's relay
contact terminals.
2-10
4204
4204
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
Figure 11. 4204 Connections to Control
(4229 Module is shown in the 4219/4229 Expansion Zones paragraph on page 2-7)
Notes
• Use 4204 or 4229 modules.
• Supervision: 4204 and 4229 modules are
supervised against removal. The module's device
address is displayed as follows if a module is
disconnected from the control's terminals, or if
the module cover is removed and the tamper
jumper is installed:
Alpha:
FAULT xx Wire Expansion
ALARM xx Wire Expansion
Fixed-Glass: lxx (or 91 if field *199 set for 2-digit
display)
where "xx is the module's address.
• If communication failure occurs on a device with
zones wired to it, all zones on the device will be
displayed in their respective partitions.
4204
Address
no. 1
12
no. 2
13
no. 3
14
no. 4
15
RELAY 4
TYPICAL
(SHOWN "OFF")
RELAY
4-PIN CONSOLE PLUG
RELAY
EITHER OR BOTH
CAN BE USED
RELAY
TB1
13 14 15 16
YEL
DATA IN
FROM CONTROL
BLK
(–) GROUND
GRN
DATA OUT
TO CONTROL
RED
(+) 12V
CHECK xx Wire Expansion
4229
no. 1 (zn 09-16)
no. 2 (zn 17-24)
no. 3 (zn 25-32)
no. 4 (zn 33-40)
no. 5 (zn 41-48)
C
NC
NO
C
3
NC
NO
C
2
NC
NO
C
1
NC
NO
TB2
Address
07
08
09
10
11