Security Manager; Summary Of Connections - ADT Safewatch Pro 3000 Installaton Manual

Hide thumbs Also See for Safewatch Pro 3000:
Table of Contents

Advertisement

24-HR BATTERY STANDBY REQUIRED FOR
BATTERY FUSE
FIRE INSTALLATIONS. USE 12V, 17.2AH
FOR REPLACEMENT,
3A
BATTERY FOR 600mA AUX POWER. SEE
USE SAME VALUE
INSTRUCTIONS.
(e.g. ADEMCO No. 90-12)
BATTERY CAPACITY FOR EMERGENCY
BURGLARY STANDBY USE AT LEAST 4 HRS
CHARGING
BLACK
BATTERY
+
VOLTAGE
FLYING LEADS
12V, 4AH
13.8VDC
RED
FOR BATTERY
+
CONNECTION
SEALED LEAD-ACID TYPE.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
TO DETERMINE TOTAL STANDBY
LOAD ON BATTERY, ADD 100mA
TO TOTAL OF AUX. POWER
OUTPUT AND REMOTE
TOUCHPAD CURRENTS.
1
2
USE UL LISTED LIMITED ENERGY
CABLE FOR ALL CONNECTIONS
PLUG-IN TRANSFORMER
16.5VAC, 25VA (e.g. ADEMCO
No. 1321).
(USE No. 1321CN IN CANADA)
TO 110VAC
USE 4300 / 1321X10 TRANSFORMER
UNSWITCHED
INTERFACE IN PLACE OF 1321
OUTLET (24HR)
OR 1321CN WHEN POWER LINE
CARRIER DEVICES ARE BEING
USED (SEE INSTRUCTIONS
FOR CONNECTIONS)
+
ALARM OUTPUT
10.5–13.8VDC, 2A MAX. (600mA MAX. FOR
UL USAGE, INCLUDING AUX POWER)
STEADY FOR BURGLARY/PANIC,
TEMPORAL PULSE SOUNDING FOR FIRE.
CAN USE ADEMCO No. 702 SIREN,
OR 12V BELL). SEE INSTRUCTIONS.
FOR COMPLETE
INFORMATION, SEE
INSTRUCTIONS
8-PIN CONNECTOR
USED FOR 4300/1321X10
TRANSFORMER
CONNECTIONS AND FOR
ON-BOARD TRIGGERS
SEE INSTRUCTIONS.
(USE SA4120XM-1
1
2
3
4
5
6 7 8
CABLE)
SYNC
COM
TO
TRANS.
DATA
TO TERM 4
RED JUMPER
TO TERM 5
CUT FOR BELL SUPERVISION.
TO TERM 6
ALSO, CONNECT 2000 OHM
TO TERM 7
RESISTOR DIRECTLY ACROSS
SOUNDER.
3
4
5
6
7
8
+
AUX. POWER
OUTPUT
10.5-13.8VDC
600mA MAX.
(500mA MAX.
FOR UL
INSTALLATIONS)
ALL OUTPUTS
ARE POWER
LIMITED.
NOTE:
TOUCHPAD (S)
CURRENT (IN
BOTH
REMOTE
PARTITIONS)
TOUCHPADS
AND ALL
AND OTHER
OTHER DEVICES
2000
ADDRESSABLE
OHMS
DRAWING
DEVICES
EOLR
POWER FROM
(e.g. 5800TM,
TERMS 4 & 5
4285/4286, LRR,
MUST BE
4219, 4229,
INCLUDED IN
4204, 5881)
AUX CURRENT
DRAIN
REMOTE TOUCHPADS
CALCULATIONS.
EACH PARTITION CAN
USE 6137B OR 6139B
TOUCHPADS. LOCAL
PROGRAMMING
MUST BE DONE WITH A
6139B BUT NEED NOT
REMAIN IN THE SYSTEM
(SET TO ADDRESS 16).
ADEMCO No. 4219
WIRED EXPANSION MODULE
(8 ADD'L EOLR WIRED ZONES)
-OR-
ADEMCO No. 4229
WIRED EXPANSION/RELAY MODULE
BLK
(8 ADD'L EOLR WIRED ZONES PLUS 2
RED
OUTPUT RELAYS)
-OR-
GRN
ADEMCO No. 4204 RELAY MODULE
YEL
(4 OUTPUT RELAYS)
AND/OR
ADEMCO 5881* Type
RF RECEIVER
BLK
WIRELESS ZONES
BLK
RED
5881L:
UP TO 8
RED
5881M: UP TO 16
GRN
GRN
5881H: UP TO 64 (48+16 BUTTONS)
YEL
*5882 IN CANADA
YEL
9
10
13
14
11
12
15
2000
2000
2000
2000
OHMS
OHMS
OHMS
OHMS
EOLR
EOLR
EOLR
EOLR
MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)
RESPONSE, ZONES 1-8: 10, 350, OR 700 MSEC (PROGRAMMABLE)
SAFEWATCH PRO 3000

SECURITY MANAGER 3000

SUMMARY OF CONNECTIONS

SET UNIT'S DIP
THIS EQUIPMENT SHOULD BE INSTALLED
SWITCH FOR
IN ACCORDANCE WITH THE NATIONAL
DEVICE
ADDRESSES
FIRE PROTECTION ASSOCIATION'S
7 - 15
STANDARD 72, CHAPTER 2 (NATIONAL
SEE
FIRE PROTECTION ASSOC.,BATTERY -
INSTRUCTIONS.
MARCH PARK, QUINCY, MA 02269).
PRINTED INFORMATION DESCRIBING
SET RECEIVER'S
PROPER INSTALLATION, OPERATION,
DIP SWITCH FOR
TESTING, MAINTENANCE, EVACUATION
DEVICE ADDRESS
PLANNING AND REPAIR SERVICE IS TO
OF "0".
SEE INSTRUCTIONS.
BE PROVIDED WITH THIS EQUIPMENT.
17
18
19
20
21
22
16
TIP
RING
(BROWN)
(GRAY)
HANDSET
TELEPHONE WIRING
(VIA RJ31X* JACK AND DIRECT
CONNECT CORD)
*CA38A IN CANADA
DOC LOAD NO.: 3
FOR CONNECTION OF OPTIONAL 4285 OR 4286 VIP
MODULES TO PHONE TERMINALS, SEE INSTRUCTIONS.
WARNING:
SHOCK, DISCONNECT TELEPHONE
LINE AT TELCO JACK BEFORE SERVICING
THIS UNIT.
2000
2000
2000
OHMS
OHMS
OHMS
COMPLIES WITH FCC RULES, PART 68.
EOLR
EOLR
EOLR
FCC REGISTRATION NO.
RINGER EQUIVALENCE:
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
WEEKLY TESTING IS REQUIRED TO ENSURE
PROPER OPERATION OF THIS SYSTEM.
ASSEMBLED IN MEXICO
23
24
25
TIP
RING
EARTH
(GREEN)
(RED)
GROUND
INCOMING
SEE
PHONE LINE
INSTRUCTIONS
FOR PROPER
GROUNDING
TO PREVENT RISK OF
File No. CS551 & CBP444
ADT3000-SOC-V0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Security manager 3000

Table of Contents