Mechanics Of Programming - ADT Safewatch Pro 3000 Installaton Manual

Hide thumbs Also See for Safewatch Pro 3000:
Table of Contents

Advertisement

Type 24
Silent Burglary
Type 25 *
24-Hour Non-Alarm
Monitor
Type 77
Keyswitch
Types 90-93
Configurable
* The system can still be armed when these zone types are in a faulted condition.
NOTE: All of the zone types described are available for the wireless portion of the system, if used.

Mechanics of Programming

To program the system from a touchpad:
• You must use a 2-line Custom English display touchpad.
• Both partitions must be disarmed.
Data Field Programming Procedures
Task
Entering Program Mode
Go to a Data Field
Entering Data
Review a Data Field
Deleting an Entry
• Usually assigned to all sensors or contacts on exterior doors and windows where
bells and/or sirens are NOT desired.
• Provides an instant alarm, with NO audible indication at any touchpad or
external sounder, if the zone is faulted when the system is armed in the Away,
Stay, or Instant, modes.
• A report is sent to the central station.
• For use with sensors designed to provide a trouble display (but no trouble
sounding) when an oil tank is low, or other similar application for critical
condition monitoring where a non-alarm response is required.
• When this zone type is faulted and remains faulted for the programmed time
duration (field *53), a special event message is sent to the central monitoring
station. The same holds true for restoration.
• Assign to zone wired to a keyswitch.
• Do not use devices assigned as input type "BR" with this zone type.
These zone types can be programmed for various custom responses. Configurable
options include response to entry/exit delays, response opens and shorts, types of
alarm and trouble sounding, dial delay, type of display, and unique Contact ID
report codes.
Procedure
A) Press both [ ∗ ] and [#] at the same time within 50 seconds after power is applied
to the control,
OR
B) After power-up, enter [Installer code (6-3-2-1)] + 8 0 0.
(method "B" is disabled if you exit the program mode using ∗ 98)
Press [ ∗ ] + [Field Number] (for example, ∗ 21).
A display of " EE " or " Entry Error " means you have entered a nonexistent field.
Simply re-enter [ ∗ ] plus a valid field number.
When the desired field number appears, simply enter the digits required. The
touchpad beeps three times after the last digit is entered and automatically
displays the next data field in sequence.
If entering less than the maximum digits available (e.g., phone number field),
enter the desired digits, then press [ ∗ ] and the next data field number to be
programmed to end the entry.
Press [#] + [Field Number].
That field's data is displayed, but no changes can be made.
Press [ ∗ ] + [Field No.] + [ ∗ ] (applies only to phone number, account number, and
pager character fields).
3-5