About Schedules

The system provides up to 32 schedules, which can be used to control up to 12 types of system events at
pre-defined times. Sixteen schedules are intended for use by the end-user, and sixteen are reserved for
the installer. In addition, some events are also reserved for the installer only (listed in the "Enter
Event" prompt paragraph below).
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating mode.
The following prompts are displayed:
PROMPT
E N T E R S C H E D N O .
0 0 = Q U I T
0 0
E N T E R E V E N T
D E V I C E N U M B E R
X X
G R O U P N U M B E R
X
P A R T I T I O N
X X
S T A R T
S M T W T F S
0 0 1 0 0 0 0
H H M M A M
VALID ENTRIES
Schedule Number
01-16 = end-user schedules
17-32 = installer-only schedules
[∗] to continue
Enter Event
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Latch Key Report to Pager
04 = Forced Stay Arming
05 = Forced Away Arming
06 = Auto Disarm
07 = Display "Reminder"
††
10 = Display custom words
11 = Periodic Test Report
†††
12 = Up and About
[∗] to continue
Device Number
01-18 = device number
[∗] to continue
Group Number
01-8 = group number
[∗] to continue
Partition
0 = all partitions
1 = partition 1
2 = partition 2
3 = common
[∗] to continue
Start Time
01-12 = hour
00-59 = minute
0 = AM; 1 = PM
Days = place "1" under days
[∗] to continue

Creating Schedules

EXPLANATION
Schedule numbers 01-16 can be programmed and changed by the end
user or installer. Schedules 17-32 can only be programmed or
changed by the installer.
Enter the desired event number for event you want to occur at a
specified time.
Events 10-12 are reserved for the installer only.
Latch key report (option 03) is sent to all pagers in the user's
partition. User must be enabled for paging (see User Attributes in
System Operation section).
† Forced bypass must be enabled in field *23.
†† if selected, system displays custom words 8, 9, and 10 at defined
time. Can be used as installer's reminder message to the end user.
†††This selection defines the large time window within which the
time window selected in data field *175 will be monitored.
This prompt appears if event "1" (relay on/off) was selected, otherwise
it is skipped.
Enter the physical device number as programmed in ∗79 Menu Mode,
then press [*] to continue to the "Start" prompt.
Device numbers 17 and 18 designate built-in triggers 1 and 2
respectively.
This prompt appears if event "2" (user access) was selected.
Otherwise it is skipped.
Press [*] to continue to the "Start" prompt.
This prompt appears if events "3-7,10,12" were selected. Otherwise it
is skipped.
Press [*] to continue to the "Start" prompt.
Enter the event's start time and days of the week to occur.
To select days, position the cursor under the desired days using the
[∗] key to move forward, then press "1" to select the day.
S E C T I O N
1 0
10-1