Safewatch Pro 3000 Installation Instructions
Interactive Mode Programming (∗56, *57, ∗58, ∗79, ∗80, ∗81, ∗82)
Entering Interactive Mode
Loading Factory Defaults/Initializing for Download
To Load Default Entries
To Initialize Download ID
Do not press 97 to load defaults if any programming has been done previously—data already
programmed into the system will be changed!
Exiting the Programming Mode
Prevent installer code reentry
Allow installer code reentry
Table of Device Addresses
Address
Report
00
100
03
103
04
104
07
107
08
108
09
109
10
110
11
111
12
112
13
113
14
114
15
115
16
n/a
17
n/a
18
n/a
19
n/a
20
n/a
21
n/a
22
n/a
23
n/a
28
n/a
† Addressable devices are identified by "1" plus the device address when reporting. Use zone 91 to
enable/disable addressable device reporting (default = reports enabled). See field *199 for
addressable device (ECP) 3-digit/2-digit identification touchpad display options.
3-6
Press [ ∗ ] + [Interactive Mode No.] (for example, ∗ 56) while in Program Mode.
The Custom English display touchpad will display the first of a series of
prompts requesting entries.
After making the appropriate entry, press the [∗] key to accept the entry and
continue to the next prompt.
Press ∗97 while in Program Mode. This resets all data fields to the ADT
default values shown in the boxes in the Program Form. Use ∗ 97 only if you
wish to return to the original factory-programmed defaults.
Press ∗96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and CSID.
Press ∗98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if ∗ 98 was
used to exit, you must first power the system down. Then power up again,
and press [∗] and [#] at the same time, within 50 seconds of powering up.
Press ∗99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [∗] and [#] at the same time,
within 50 seconds of power-up.
Device
RF Receiver
Long Range Radio
4286 Voice Module
Zone Expanders (4219/4229):
module 1 zones 09 - 16
module 2 zones 17 - 24
module 3 zones 25 - 32
module 4 zones 33 - 40
module 5 zones 41 - 48
Relay Modules (4204):
module 1
module 2
module 3
module 4
Touchpads:
touchpad 1
touchpad 2
touchpad 3
touchpad 4
touchpad 5
touchpad 6
touchpad 7
touchpad 8
5800TM Module
Programmed by...
*56 zone programming: input device type entry
automatic if output to long range radio field *29 enabled
automatic if phone module access code field *28 enabled
*56 zone programming: input device type entry, then:
• automatically assigned if zone number 9-16 entered as AW type
• automatically assigned if zone no. 17-24 entered as AW type
• automatically assigned if zone no. 25-32 entered as AW type
• automatically assigned if zone no. 33-40 entered as AW type
• automatically assigned if zone no. 41-48 entered as AW type
*79 output device programming: device address prompt:
• entered at device address prompt
• entered at device address prompt
• entered at device address prompt
• entered at device address prompt
data filed programming as listed below:
• always enabled for partition 1, all sounds enabled.
• data field *190
• data field *191
• data field *192
• data field *193
• data field *194
• data field *195
• data field *196
automatic