Measured value memory Relative measuring, Adjust sensor, cancel: press and hold down To switch ON with press keys : Reinitialization Device configuration M▲ Softwareversion Rear of device (4) Battery compartment 3 AA alkaline-manganese batteries THERM 2420...
When you unpack the device check carefully for any signs of transport damage and ensure that delivery is complete. Measuring instrument THERM 2420 with 3 AA alkaline batteries These operating instructions In the event of transport damage please retain the packaging material and in- form your supplier immediately.
Before you touch any sensor lines, ensure that all static electricity has been discharged. 4. INTRODUCTION The THERM 2420 measuring instrument has just one measuring input with a miniature thermal socket suitable for connecting most thermocouple sensors. For operation purposes the device incorporates a large LCD display and a key- pad.
The various possible types and their measuring ranges are listed in Section 10.1. To con- nect your own existing sensors you simply need the appropriate miniature ther- mal connector, ensure that these are correctly polarized. THERM 2420...
8. DISPLAY AND KEYPAD 8.1 Display The display (5) on the THERM 2420 measuring instrument is a 2-row LCD ar- rangement; the main field comprises 5x 7-segment digits (d) plus 2x 16-seg- ment digits (c) for depicting the measured value; the function field comprises 41/2x 7-segment digits (b) for depicting various measuring functions (a);...
Displaying the maximum value : (see Section 9.3) To delete press and hold down Displaying the minimum value : (see Section 9.3) To delete press and hold down Zero-setting the measured value : (see Section 9.5) To delete press and hold down THERM 2420...
To select the measured value function press keys : M▲ M▼ Units in °F Voltage in mV Cold junction temperature By default changing the measured value functions is locked in the device configuration (display ´LOC´) and must first be unlocked(see Section 10.3). THERM 2420...
As soon as you clear the memory, the current measured value will appear (be- cause measuring is continuous). 9.4 Measured value memory On the THERM 2420 any measured value can be saved. To save the measured value press The currently saved value then ap- pears in the function field preceded by the symbol ´M´.
Device configuration 10. DEVICE CONFIGURATION On the THERM 2420 measuring instrument a number of parameters can be configured. To do so when switching ON press and hold down . The function field should then show an abbreviation for the parameter and the main field should show the value currently set.
Measuring functions and relative measuring (default) 11. TROUBLE-SHOOTING The THERM 2420 measuring instrument can be configured. If in certain cir- cumstances the device does not respond exactly as it should, the cause of such unexpected behavior is only very rarely a device defect; more usually it is incorrect operation by the user, an invalid setting, or unsuitable cabling.
Electromagnetic compatibility (EMC) 12. ELECTROMAGNETIC COMPATIBILITY (EMC) The THERM 2420 measuring instrument complies in full with the safety re- quirements specified in the EU directive relating to electromagnetic compatibili- ty (EMC) (89/336/EWG). The following standards have been applied in evaluating the product.
Peak value memory Power supply 13.1 6, 14 Product overview 13.2 reference value reinitialization Relative measuring Scope of delivery Suitable conditions 13.1 supply voltage monitoring Switching ON / OFF Technical data 13.1 To switch OFF To switch ON Trouble-shooting Warranty THERM 2420...