3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem remains and no other DIMMs have the same indication, replace the DIMM.
• 806f0a0c-20070107 : An Over-Temperature Condition has been detected on the memory device
7 in Group 1 on Subsystem System Memory.
An overtemperature condition has been detected in the DIMM in DIMM connector 7.
May also be shown as 806f0a0c20070107 or 0x806f0a0c20070107
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0146
User Response
Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or
cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem remains and no other DIMMs have the same indication, replace the DIMM.
• 806f0a0c-20080108 : An Over-Temperature Condition has been detected on the memory device
8 in Group 1 on Subsystem System Memory.
An overtemperature condition has been detected in the DIMM in DIMM connector 8.
May also be shown as 806f0a0c20080108 or 0x806f0a0c20080108
Severity
Error
Serviceable
Yes
450
Flex System x220 Compute Node Installation and Service Guide

Advertisement