Lenovo Flex System x220 Installation And Service Manual page 407

Compute node
Hide thumbs Also See for Flex System x220:
Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0062
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
• 806f0507-2584ffff : [ProcessorElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Processor Configuration
Mismatch has occurred. All CPUs. One of CPUs.
May also be shown as 806f05072584ffff or 0x806f05072584ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0062
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
806f050c-2001ffff : Memory Logging Limit Reached for DIMM 1 on Subsystem
[MemoryElementName].
This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
.
Chapter 6
Troubleshooting
399