Lenovo Flex System x220 Installation And Service Manual page 404

Compute node
Hide thumbs Also See for Flex System x220:
Table of Contents

Advertisement

codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
• 806f0413-3101ffff : A PCI PERR has occurred on system [ComputerSystemElementName].
A PCI parity error has been detected in the I/O expansion adapter in PCIe adapter slot 1 in the PCI
expansion unit.
May also be shown as 806f04133101ffff or 0x806f04133101ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0232
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
• 806f0413-3102ffff : A PCI PERR has occurred on system [ComputerSystemElementName].
A PCI parity error has been detected in the I/O expansion adapter in PCIe adapter slot 1 in the PCI
expansion unit.
May also be shown as 806f04133102ffff or 0x806f04133102ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50