Lenovo Flex System x220 Installation And Service Manual page 341

Compute node
Hide thumbs Also See for Flex System x220:
Table of Contents

Advertisement

The previously high temperature of the PEN Mezzanine Expansion adapter in I/O expansion connector
4 has returned to below its specified threshold.
May also be shown as 800704012c04ffff or 0x800704012c04ffff
Severity
Warning
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0526
User Response
Information only; no action is required.
• 80070601-2c01ffff : Sensor Mezz Exp 1 temp has transitioned to non-recoverable.
The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified
threshold. The compute node has attempted a soft shutdown.
May also be shown as 800706012c01ffff or 0x800706012c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0530
User Response
Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or
cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers
are in place and correctly installed.
.
Chapter 6
Troubleshooting
333