Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
PCIe adapter slot 4 in the PCI expansion unit must not be empty. Install either a PCIe adapter or a filler
in this slot. If a baffle or PCIe adapter card is installed in the slot, remove the riser and reseat the card,
then reinstall the riser into the PEN to clear the critical error. If the error does not clear after reseating
the PCEi card or baffle, then replace the riser to resolve the alert If replacing the riser does not resolve
the alert, then replace the PCIe adapter card or baffle. If replacing the both the riser and the PCIE
adapter card or baffle does not resolve the defect, then replace the system planar in the PEN.
• 80070219-0701ffff : Sensor Sys Board Fault has transitioned to critical from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702190701ffff or 0x800702190701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
• 8007021b-0301ffff : Sensor CPU 1 QPILinkErr has transitioned to critical from a less severe state.
CPU 1 QPI Link Failure detected.
322
Flex System x220 Compute Node Installation and Service Guide