Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
If the Full Height Riser (FHR) is not installed in the PEN, then the FHR needs to be installed in the
PCIe Expansion Node (PEN) to remove this alert and allow the system to power on. If the FHR is
installed, then remove the Compute Node and PEN from the chassis, and remove the FHR. Reinstall
the FHR in the base planar in the PEN, and verify if this alert has been cleared. If this alert continues
to occur, then replace the FHR. If after replacing the FHR, the alert continues to occur, then replace
the base planar on the PEN.
• 80070217-0b82ffff : Sensor PEN LPR Empty has transitioned to critical from a less severe state.
The Low Profile Riser Card in the PEN has been detected as missing The PCIe Expansion Node will not
power on without this card installed.
May also be shown as 800702170b82ffff or 0x800702170b82ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
If the Low Profile Riser (LPR) is not installed in the PCIe Expansion Node (PEN), then the LPR needs
to be installed in the PEN to remove this alert and allow the system to power on. If the LPR is
installed, then remove the Compute Node and PEN from the chassis, and remove the LPR. Reinstall
the LPR in the base planar in the PEN, and verify if this alert has been cleared. If this alert continues
to occur, then replace the LPR. If after replacing the LPR, the alert continues to occur, then replace
the base planar on the PEN.
316
Flex System x220 Compute Node Installation and Service Guide