Prefix: PLAT ID: 0522
User Response
Complete the following steps:
1. Remove any recently installed components.
2. Try to power on the compute node.
– If the compute node successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are
compatible with the compute node.
b. Inspect the previously installed components for physical damage.
– If the compute node does not successfully power on or if this is not the first occurrence
of this problem, replace the system board.
• 8007020f-2582ffff : Sensor No I/O Resources has transitioned to critical from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007020f2582ffff or 0x8007020f2582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0522
User Response
No I/O Resources :
• 80070214-2201ffff : Sensor TPM Lock has deasserted the transition from normal to non-critical
state.
The TPM Lock has returned to normal.
May also be shown as 800702142201ffff or 0x800702142201ffff
Severity
Error