codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
806f010c-2581ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected a Memory uncorrectable error. All
DIMMs. One of the DIMMs.
May also be shown as 806f010c2581ffff or 0x806f010c2581ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
User Response
This is a UEFI detected event. To find the UEFI diagnostic code for this event, in the information
center, follow the instructions in "Finding the UEFI diagnostic code" under "UEFI diagnostic
codes." Then, in the information center, open the topic for the UEFI diagnostic code and follow the
instructions under "User response."
• 806f010d-0400ffff : The Drive Drive 0 has been disabled due to a detected fault.
The hard disk drive controller has detected a fault in hard disk drive 0. Hard disk drive 0 is now defunct.
May also be shown as 806f010d0400ffff or 0x806f010d0400ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5